A railway station expects 900 passengers to enter a temporary waiting area during a 15-minute surge. For an initial sizing estimate, assume passengers arrive at a steady rate throughout that surge, each waits about eight minutes, and everyone needs 1.2 square metres of usable standing and circulation space. The waiting area is initially empty and passengers depart after waiting; the planner cares about the busiest moment, not the total daily footfall.
Estimate the floor area needed once arrivals have been flowing long enough to fill the queue. State the main assumption that could make this estimate too small, and illustrate the issue if 600 of the 900 passengers actually arrived during the first five minutes and all waited exactly eight minutes.
Get hint
Hint 1
Translate the 900 arrivals into people per minute, then multiply by the typical time each remains waiting.
Show solution
The average arrival rate in the specified surge is
\[
\lambda=\frac{900\text{ passengers}}{15\text{ minutes}}=60\text{ passengers/minute}.
\]
Under a regular flow with a typical eight-minute wait, the approximate number simultaneously waiting is arrival rate times average residence time (a version of Little's law):
\[
N\approx60\text{ passengers/minute}\times8\text{ minutes}=480\text{ passengers}.
\]
At 1.2 square metres per passenger, the estimated usable area is \(480(1.2)=\boxed{576\text{ m}^2}\). The dimensional cancellation of minutes provides a simple consistency check. The initially empty queue fills during the first eight minutes and then, under constant arrivals and waits, stabilizes around 480 people until the surge ends.
A critical assumption is that the 900 arrivals are spread fairly evenly through the 15 minutes. Suppose instead 600 passengers arrive over the first five minutes and each stays exactly eight minutes. Immediately after minute five none of those first 600 can yet have left, so occupancy is already 600, requiring \(600(1.2)=\boxed{720\text{ m}^2}\), 25% more usable area than the estimate. Still longer waits, blocked exits or more extreme bunching could also increase the peak. This is an order-of-magnitude planning estimate, not a guaranteed maximum for arbitrary arrival patterns.
Assumptions
The 900 people enter during a single 15-minute burst; all use the same waiting space.
The initial estimate assumes steady arrivals and approximately eight-minute residence, with no other capacity restriction.
The illustrative clustered-arrival case assumes exactly eight-minute waits to make the five-minute lower bound on peak occupancy unambiguous.
Final Answer
Steady-flow estimate: 480 people simultaneously, needing 576 m². In the illustrated five-minute clustering, at least 600 people are present just after minute 5, needing 720 m²; the steady-rate assumption would underestimate the peak.